EX10XX Series
The EX1000A (pictured), EX1000A-TC, and EX1000A-TCDC are advanced full-featured thermocouple and voltage measurement instruments. The EX1016A, EX1032A, EX1048A, and EX10SC are advanced full-featured thermocouple and voltage measurement instruments. Request A Quote |
-
Overview
-
Models
-
Manuals
-
Data Sheets
-
Software
-
Drivers
-
Other
FLEXIBLE CHANNEL CONFIGURATION
A wide range of measurement types, including pressure, strain, temperature, position and voltage, can be performed using this instrument when combined with the EX10SC signal conditioning expansion chassis. Each input incorporates an independent signal conditioning path with software selectable filters for maximum flexibility.
END-TO-END SELF-CALIBRATION
Complete end-to-end self-calibration is provided for each signal path on a programmable basis. Self-calibration is simple and quick, and can be performed as often as desired.
SCALABLE FOR SYNCHRONIZED HIGH-SPEED, HIGH CHANNEL COUNT
With LXI complaint features like built-in LXI Trigger Bus and IEEE-1588 time-stamping, the EX1000A, EX1000A-TC, and EX1000A-TCDC support simplified distribution, synchronization and scalability for high-channel count applications. They can also be easily integrated with other platforms such as VXI and PXI.
BUILT IN COLD JUNCTION COMPENSATION (CJC) AND OPEN THERMOCOUPLE DETECTION (OTD)
The heart of any truly accurate thermocouple measurement system is the CJC implementation. These instruments combine multiple precision thermistors, a significant thermal mass, and careful parts placement to provide world-class measurement performance. Each temperature channel is configured with open transducer detection functionality, providing a continuous indication of the channel status. Open transducer detection can be activated or deactivated on a per-channel basis.
A wide range of measurement types, including pressure, strain, temperature, position and voltage, can be performed using this instrument when combined with the EX10SC signal conditioning expansion chassis. Each input incorporates an independent signal conditioning path with software selectable filters for maximum flexibility.
END-TO-END SELF-CALIBRATION
Complete end-to-end self-calibration is provided for each signal path on a programmable basis. Self-calibration is simple and quick, and can be performed as often as desired.
SCALABLE FOR SYNCHRONIZED HIGH-SPEED, HIGH CHANNEL COUNT
With LXI complaint features like built-in LXI Trigger Bus and IEEE-1588 time-stamping, the EX1000A, EX1000A-TC, and EX1000A-TCDC support simplified distribution, synchronization and scalability for high-channel count applications. They can also be easily integrated with other platforms such as VXI and PXI.
BUILT IN COLD JUNCTION COMPENSATION (CJC) AND OPEN THERMOCOUPLE DETECTION (OTD)
The heart of any truly accurate thermocouple measurement system is the CJC implementation. These instruments combine multiple precision thermistors, a significant thermal mass, and careful parts placement to provide world-class measurement performance. Each temperature channel is configured with open transducer detection functionality, providing a continuous indication of the channel status. Open transducer detection can be activated or deactivated on a per-channel basis.
EX1000A | 48-Channel Precision Voltage Measurement Instrument |
EX1000A-TC | 48-Channel Precision Thermocouple and Voltage Measurement Instrument |
EX1000A-TCDC | 48-Channel Precision Thermocouple and Voltage Measurement Instrument, DC Powered |
EX1016A |
16-Channel Precision Thermocouple, 32-Channel Precision Voltage Measurement Instrument |
EX1032A |
32-Channel Precision Thermocouple, 16-Channel Precision Voltage Measurement Instrument |
EX1048A |
48-Channel Precision Thermocouple Measurement Instrument |
EX10SC |
16-Channel Signal Conditioning Expansion Chassis |
Title
Document
Download
EX10xxA - Command Line Tools - Linux - 72-0262-100 (Rev:1.7.0)
DocumentEX10xxA - Command Line Tools - Linux - 72-0262-100 (Rev:1.7.0)
Title
Document
Download
EX10xxA IVI Driver 32 Bit - 72-0267-000 (Rev:2.0.5)
DocumentEX10xxA IVI Driver 32 Bit - 72-0267-000 (Rev:2.0.5)
EX10xxA IVI Driver 64Bit - 72-0267-100 (Rev:2.0.3)
DocumentEX10xxA IVI Driver 64Bit - 72-0267-100 (Rev:2.0.3)
Compact LXI Data Acquisition System Saves Gas Turbine Manufacturer Time and Ensures Reliability (Rev:A)
Gas Turbine Test Capabilities (Rev:A)
HALT/HASS Testing Drives Product Reliability (Rev:A)
High-Performance LXI DAQ System Vital for Blood Storage (Rev:A)
How to Maximize Temperature Measurement Accuracy - TechnicalNote (Rev:14A)
Implementing Advanced Cold-Junction Compensation Techniques to Improve Temperature Measurement Accuracy (Rev:14A)
Solid Rocket Motor Case Study (Rev:A)
Title
Document
Download
Compact LXI Data Acquisition System Saves Gas Turbine Manufacturer Time and Ensures Reliability (Rev:A)
DocumentCompact LXI Data Acquisition System Saves Gas Turbine Manufacturer Time and Ensures Reliability (Rev:A)
HALT/HASS Testing Drives Product Reliability (Rev:A)
DocumentHALT/HASS Testing Drives Product Reliability (Rev:A)
High-Performance LXI DAQ System Vital for Blood Storage (Rev:A)
DocumentHigh-Performance LXI DAQ System Vital for Blood Storage (Rev:A)
How to Maximize Temperature Measurement Accuracy - TechnicalNote (Rev:14A)
DocumentHow to Maximize Temperature Measurement Accuracy - TechnicalNote (Rev:14A)
Implementing Advanced Cold-Junction Compensation Techniques to Improve Temperature Measurement Accuracy (Rev:14A)
DocumentImplementing Advanced Cold-Junction Compensation Techniques to Improve Temperature Measurement Accuracy (Rev:14A)